Intelligent parking management system construction wiring eight points

With the difficulty of parking getting more and more attention, many domestic parking lots are installing intelligent parking systems. Traditional parking systems have gradually been eliminated. With the development of society, parking management systems are also widely used in various industries. . The use of parking management system, it will inevitably have to give the parking management system construction wiring, if the installation is not in place during construction wiring, it will affect the use of parking management system, here's a look at how to correctly and reasonably smart parking Field system construction wiring.

1. The signal cable of the control board used by the parking lot system cannot be laid in parallel with the AC power line, so it should be avoided in the same PVC pipe.

Second, the parking lot system needs to avoid the wires from producing joints when wiring. If there must be a joint, the joint should also be crimped or welded and waterproofed.

Third, the parking lot wiring All external devices connected to the head can not be too long, so as to avoid exposure caused by short-circuit phenomenon, the parking system wiring must be marked on the cable to facilitate the future installation, commissioning and maintenance.

4. If the entrance and exit of the parking lot is on a slope, the control chassis needs to be installed on a flat road surface, or a cement pouring platform. It is recommended to avoid the situation where the vehicle starts half ramp at the time of swiping.

5. Before cleaning the parking lot, brush the hole of the pipe. When passing the cable, grease or talcum powder should be applied. The cable that enters the nozzle should be kept straight. Measures such as moisture-proof and anti-corrosion should be taken.

Sixth, the general sense of the ground coil installation can choose polyethylene AWG16-22 multi-core high temperature sheathed wire, do not use PVC insulated wire, the wiring of the ground coil is to cut the ground a deep 10 cm, 2X0.8M square nest, four When the corners are cut into 45° bevels, it is recommended that the coils be placed in a circle. Under normal circumstances, 5-6 layers are placed. The coils are preferably pressed tightly between each layer, and there is no joint inside the coils. The inductive coil output is twisted to the barrier, and the shorter the distance, the better. After the connection is completed, the nest is sealed with dry cement.

7. During the wiring of the parking lot system, the distance between each equipment should be properly adjusted according to the site conditions. If there is no equipment in the system, the wire required for the equipment need not be laid, and the size of the entrance and exit control machines, entrance and exit parking lot gates, and entrance and exit cameras Place the same position, the same size coil.


VIII. If the booth of the parking lot management and charging system is equipped with air conditioning, the AC power used in the wiring of the parking lot system must be routed separately, and it must not be routed in the same slot as the signal line and the low voltage DC power line. At the same time, it is recommended that the size of the AC power cord to be supplied should have sufficient margin.

Smart parking is a method to solve parking difficulties. Transforming urban traffic to make full use of Internet means meeting people’s working, living, and entertainment environments with a more scientific, standardized, effective, fast, safe, and convenient intelligent parking lot automatic management system is a goal. The parking management system will provide a more secure, comfortable, convenient, fast and open intelligent and information-based living space, and better promote the healthy development of the human environment.

Dreida, a manufacturer of car park management systems, focuses on parking for 15 years! If you have any problems with parking systems, please pay attention to Dreida or pay attention to Deliyun WeChat public number: deliyun-cn. Welcome to consult and exchange.


We can produce various kinds of nails, including Common Nail, dry wall screws , stainless steel nail,Roofing Nail,

roofing nail with umbrella head,wood screws,self-drilled screws,self tapping screws and other kinds of nails. 

We also can design and produce according to customer's special requirements.


common wire nails



roofing nail

Concrete-Nail


Nail Products

Nail Products,Umbrella Head Roofing Nails,Stainless Steel Nails,Umbrella Roofing Nail

Hebei Mingda International Trading Co.,Ltd , https://www.amazingcastings.com