8 Channel Pipette, Mechanical Micropette. (adjustable and fixed)

Model NO.: Toppette 8
Origin: Zhejiang
HS Code: 841390000
Model NO.: Toppette 8
Origin: Zhejiang
HS Code: 841390000
Autoclavable Pipette (Adjustable & Fixed)
All pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.

Fully autoclavable
The MicroPette plus pipettes can be fully autoclaved and withstand steam sterilization at 121ºC, 1 atm for 20 minutes. They can be autoclaved without special preparations. After autoclaving, the pipette must be cooled down and left to dry for over 12 hours.

It is recommended to check the performance of the pipette after each autoclaving. It is also advised to grease the piston and seal of the pipette after every 10 autoclaving cycles.

8 Channel Pipette, Mechanical Micropette. (adjustable and fixed)

 
Features for MicroPette plus
- Fully autoclavable
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- Covers a volume range from 0.1μl to 10ml
- Easy to calibrate and maintain with provided tools
- Design helps avoid repetitive strain injuries
- Made from innovative materials
- Calibrated in accordance with ISO8655. Each pipette comes with an individual test certificate

Features for multi-channel MicroPette plus
- Available in 8 and 12 channel configurations for standard 96-well plates
- Dispensing head rotates for optimal pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Compatible with universal style pipette tips

   
Calibration

Please visit our website for online calibration at www.dragon-lab.com. Through the online calibration software, users can perform simple, accurate, and timely calibration at no cost, and avoid calibration errors due to non-professional operation.
 
We will support and help you achieve consistently excellent results.
 




Specifications
Single-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
0.1-2.5μL 0.05μL 2.5μL 2.50% 0.0625 2.00% 0.05
1.25μL 3.00% 0.0375 3.00% 0.0375
0.25μL 12.00% 0.03 6.00% 0.015
0.5-10μL 0.1μL 10μL 1.00% 0.1 0.80% 0.08
5μL 1.50% 0.075 1.50% 0.075
1μL 2.50% 0.025 1.50% 0.015
2-20μL 0.5μL 20μL 0.90% 0.18 0.40% 0.08
10μL 1.20% 0.12 1.00% 0.1
2μL 3.00% 0.06 2.00% 0.04
5-50μL 0.5μL 50μL 0.60% 0.3 0.30% 0.15
25μL 0.90% 0.225 0.60% 0.15
5μL 2.00% 0.1 2.00% 0.1
10-100μL 1μL 100μL 0.80% 0.8 0.15% 0.15
50μL 1.00% 0.5 0.40% 0.2
10μL 3.00% 0.3 1.50% 0.15
20-200μL 1μL 200μL 0.60% 1.2 0.15% 0.3
100μL 0.80% 0.8 0.30% 0.3
20μL 3.00% 0.6 1.00% 0.2
50-200μL 1μL 200μL 0.60% 1.2 0.15% 0.3
100μL 0.80% 0.8 0.30% 0.3
50μL 1.00% 0.5 0.40% 0.2
100-1000μL 5μL 1000μL 0.60% 6 0.20% 2
500μL 0.70% 3.5 0.25% 1.25
100μL 2.00% 2 0.70% 0.7
200-1000μL 5μL 1000μL 0.60% 6 0.20% 2
500μL 0.70% 3.5 0.25% 1.25
200μL 0.90% 1.8 0.30% 0.6
1000-5000μL 50μL 5000μL 0.50% 25 0.15% 7.5
2500μL 0.60% 15 0.30% 7.5
1000μL 0.70% 7 0.30% 3
2-10mL 0.1mL 10mL 0.60% 60 0.20% 20
5mL 1.20% 60 0.30% 15
2mL 3.00% 60 0.60% 12
8-channel Adjustable Volume Pipettes
Volume Range Increment Test Volume Maximum permissible systematic error (Inaccuracy) Maximum permissible random error (Imprecision)
% μL % μL
0.5-10μL 0.1μL 10μL 1.50% 0.15 1.50% 0.15
5μL 2.50% 0.125 2.50% 0.125
1μL 4.00% 0.04 4.00% 0.04
5-50μL 0.5μL 50μL 1.00% 0.5 0.50% 0.25
25μL 1.50% 0.375 1.00% 0.25
5μL 3.00% 0.15 2.00% 0.1
50-300μL 5μL 300μL 0.70% 2.1 0.25% 0.75
150μL 1.00% 1.5 0.50% Exhaust Downpipe